More Information
Submitted: March 14, 2022 | Approved: March 28, 2022 | Published: March 29, 2022
How to cite this article: Vesper S, Libuit KG, Esguerra N. Cross A. Assessment of mold contamination in hurricane-damaged homes in Houston, Texas after sanitization by volunteers. Ann Civil Environ Eng. 2022; 6: 003-007.
DOI: 10.29328/journal.acee.1001033
Copyright License: © 2022 Vesper S, et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Keywords: Mold; Sanitized; ERMI-like; Volunteers; Air samples
Assessment of mold contamination in hurricane-damaged homes in Houston, Texas after sanitization by volunteers
Stephen Vesper1*, Kevin G Libuit2, Nicolas Esguerra3 and Andrew Cross4
1United States Environmental Protection Agency, 26 W. Martin Luther King Drive, Cincinnati, Ohio, 45268, USA
2Theiagen Genomics, LLC, Highlands Ranch, Colorado, USA
3Yale Jackson Institute for Global Affairs, New Haven, CT, USA
4All Hands and Hearts, Brooklyn, NY, USA
*Address for Correspondence: Stephen Vesper, United States Environmental Protection Agency, 26 W. Martin Luther King Drive, Cincinnati, Ohio, 45268, USA, Email: vesper.stephen@epa.gov
The purpose of this pilot study was to evaluate the effectiveness of mold sanitation in homes that suffered hurricane-related water damage. After a home is flooded, sanitation of the structure for mold is necessary before the interior of the home can be rebuilt. In this study, homes (n = 6) in Houston, Texas that had been flooded by Hurricane Harvey were sanitized by volunteers. At either 6, 8, 15, 25, 34, or 56 days after the sanitation was completed, a Button™ sampler was used to collect a 48-hour air sample, so that the mold cells in the air could be quantified. Each air sample was then analyzed by quantitative PCR (qPCR) assays for the 36 molds in the Environmental Relative Moldiness Index (ERMI) panel of indicator molds. Quantifying the 36-ERMI molds in air samples results in “ERMI-like” values. The ERMI-like values in the sanitized homes were inversely correlated (Pearson p - value 0.04) with the log of the number of days after the sanitation was completed, an indication that it takes time after sanitation for the mold levels to stabilize. This pilot study demonstrated that the ERMI-like metric was useful in assessing post-sanitation mold levels in previously flooded homes.
Hurricanes often result in water damage to homes which can promote mold growth [1,2]. Mold exposure can lead to adverse health effects, including asthma, allergies, and other respiratory problems [3]. Currently, there is no threshold for mold exposure in the US [4]. Other countries, however, have suggested various limits to indoor mold levels.
In Japan, the indoor airborne fungal levels are suggested to be maintained under 1,000 colony forming units (CFU)/m3 air, or the indoor/outdoor (I/O) ratio under 2, in cases where the fungal levels exceed 1,000 CFU/m3 air [5]. The European Collaboration Action categorized airborne fungal levels exceeding 1,000 CFU/m3 air as “high” and those exceeding 10,000 CFU/m3 air as “very high” [6]. Unfortunately, culturing air samples to estimate fungal/mold contamination has many limitations, including short sampling times, differences in culture-medium requirements, difficulty in spore identification, etc. [7].
As an alternative to culturing fungi/molds from air samples, quantitative PCR (qPCR) assays for many common molds were developed [8]. To quantify mold levels in homes, the Environmental Relative Moldiness Index (ERMI) was created [9]. The ERMI metric was based on the analysis of dust samples that were collected in the 2006 HUD Healthy Homes Survey from 1,096 representative homes across the US [9]. Each dust sample was analyzed for 36 indicator molds categorized into two groups; 26 Group 1 molds associated with water damage and 10 Group 2 molds that primarily originate from the outside air. Studies have shown that the ERMI metric is useful in assessing the relationship between mold exposures and asthma [10]. However, the ERMI metric is based on the analysis of a dust sample that is not available in a recently sanitized home. Therefore, a 48-hour air sample was used to create an ERMI-like metric for use in analyzing mold levels when a dust sample is not available.
The ERMI-like metric was described in an earlier study of the effectiveness of high-efficiency particulate air (HEPA) filtration treatment in reducing indoor air contamination in the homes of children with asthma [11]. Like the ERMI metric, the sum of the logs of the Group 2 molds (hereafter, sum Group 1) was subtracted from the sum of the logs of the Group 1 molds (hereafter, sum Group 2). However, since the results are from air samples, not dust, the term ERMI-like was used to clarify the difference from the ERMI [11]. The ERMI-like metric was found to be effective in quantifying the reduction in mold contamination in HEPA-treated homes of children with asthma [11]. In this study, the effectiveness of the mold sanitation of flooded homes was evaluated using the ERMI-like metric.
After Hurricane Harvey had flooded homes in Houston, volunteers helped six families by performing mold sanitation in their homes. The homes were sanitized between October 19 and November 30, 2017.
The first step in the sanitation process was the removal of all non-structural materials from the home like clothes, curtains, furniture, or appliances. Any visibly, water-damaged material, like drywall and flooring, were removed. Then all nails, screws, staples, and residual scraps of material were removed. A digital moisture meter (MMD4E Moisture Meter, General Tools Company, Cincinnati, OH, USA) was then used to measure the moisture level in the wooden framing. After the moisture level was determined to be below 17%, the team then scrubbed the full area of all exposed surfaces in the home with hard bristle brushes. If the home gutting process included the ceiling or the ceiling joists, these surfaces were scrubbed also. Walls were scrubbed by starting at the top (ceiling) and then down to the floor. Every square inch of the gutted area was scrubbed seven times. One scrub includes an up and down motion on the same area (scrub up/down, left/right, clockwise/counter-clockwise).
After the walls and/or ceiling in a room were scrubbed, the floor was scrubbed. A hard bristle push broom was used to cover the entire surface area of the floor. Then the team vacuumed all exposed and scrubbed surfaces in the home. (Brush attachments were used to brush down all surfaces while vacuuming.) After the vacuum work was complete, a commercial cleaning agent called ShockWave™ (Fiberlock Technologies, Inc., Andover, MA, USA) was prepared by mixing the concentrate and water, following the manufacturer’s instructions. The ShockWave™ mix was then sprayed lightly/evenly over the surface area of the scrubbed and vacuumed areas. The home was then allowed to dry.
Before any rebuilding, the post-sanitation mold levels were evaluated either at 6, 8, 15, 25, 34, or 56 days after the sanitation protocol was completed. The number of days varied for each home because of the complex schedules of the volunteers and homeowners. After the six homes had been sanitized, air samples were collected by the volunteers, as directed by the lead EPA researcher, onto 25-mm diameter, 1-µm pore-size PTFE filters (Merck Millipore, Billerica, MA) using a Button™ sampler (SKC, Inc., Eighty-Four, PA, USA) [11]. Air samples were taken at a flow rate of 4 l/min for 48-hours using SKC potable pumps (SKC, Inc.). The Button™ samplers were returned to the US EPA laboratory for removal of the filter from the Button™ sampler, under controlled conditions, followed by the mold analysis.
Each filter was placed into a 2-ml extraction tube containing 0.3 g of glass beads and the DNA extracted and purified, as previously described [12]. Then, each of the 36 molds that make up the ERMI panel was quantified using qPCR assays [8]. The resulting data was described as cell equivalents (CE) per filter for each of the 36 molds. Then the data was divided by the volume of air per sample yielding a concentration of CE per cubic meter of air sampled (CE/m3 air). The sum Group 2 value was then subtracted from the sum Group 1 value to generate the ERMI-like value for each home, as previously described [11].
Pearson correlations analysis was used to determine the correlation between ERMI-like values, the sum Group 1, or sum Group 2 values, and the log of the days after sanitation was completed. The Student T - test was used to evaluate the significance of the differences in average ERMI-like values, the sum Group 1, or sum Group 2 values in the set of three homes sampled less than 25 days after sanitation compared to the set of three homes sampled 25 days or longer after sanitation.
Table 1 shows the results of the qPCR analysis of the air-sample filters for each of the 36 ERMI-panel molds in each of the six homes in Houston, which were sampled at either 6, 8, 15, 25, 34, or 56 after the mold sanitation was completed. All homes received the same sanitation treatment and therefore each home appeared to the volunteers to be fully sanitized when the sanitation was completed, i.e., free of water damage and visible mold. The ERMI-like values and the values of the sum Group 1 mold were significantly (p - values for both 0.04) inversely correlated with the log of the days after sanitation (Table 2). By contrast, the sum of Group 2 molds was not significantly (p = 0.13) correlated with the log of the days after sanitation (Table 2).
The average ERMI-like value for the set of three homes sampled at less than 25 days after sanitation was 16.6 compared to 4.1 for the set of three homes sampled after 25 or more days. The latter set of three homes had significantly (p = 0.009) lower average ERMI-like values (Table 3). The average sum of Group 1 molds for the set of three homes sampled at less than 25 days after sanitation was 26.2 compared to 8.3 for the set of three homes sampled after 25 or more days. The latter set of homes had significantly (p = 0.001) lower average sum Group 1 mold values. However, the average sum Group 2 values were not significantly different between the two sets of homes (p = 0.08).
The goal of home sanitation/remediation is to eliminate all active mold growth, all surface spores, and the possibility of continued mold growth in flood-impacted homes. In earlier studies after Hurricane Katrina, increased mold levels were reported in flooded areas in New Orleans [13-15], followed by increases in lung and respiratory diseases [16]. Although some studies reported that remediation reduced microbial contamination [2,17], other studies found that remediation was less than completely effective [13,18,19]. The problem has been the lack of standardization in evaluating the sanitation/remediation efforts to reduce mold.
The results from this small, pilot-study indicate that a 48-hour air sample may provide a useful metric to evaluate the effectiveness of mold sanitation efforts. Ideally, the ERMI-like values in these homes would have been measured immediately after the sanitation was completed and then periodically afterward to determine when the ERMI-like values had stabilized. This goal became impractical because of the demands on the volunteers’ time.
Nevertheless, after sanitation, it appears to take several weeks (> 25 days) for the ERMI-like values to be reduced compared to the lesser time frame of < 25 days. The water-damage mold population, sum Group 1, also seems to be reduced more slowly, perhaps because it takes longer for the home to completely dry and the residual Group 1 mold spores to dissipate. On the other hand, the outside mold population, sum Group 2, seemed to equilibrate quickly, probably because these gutted homes were open to the outside air. However, a more rigorous post-sanitation, the mold-monitoring schedule will be needed to confirm the success of the sanitation protocol.
This study has the many limitations that one might expect in the middle of an ongoing disaster, specifically the small number of homes evaluated. Logistically, it was very difficult to conduct a larger study when the volunteers were focused on helping as many families as possible. Nevertheless, the results of this study show the potential value of using the ERMI-like metric to evaluate home-sanitation efforts. In preparation for future hurricanes, it would be appropriate to have trained teams available for rapid sanitation responses and mold testing.
This pilot study shows the potential value of the ERMI-like metric for the assessment of the effectiveness of home sanitation, but larger studies with additional post-sanitation sampling are needed to confirm this finding.
Author Contributions: This study was conceived by S.V. and K.G.L.; conducted by N.E. and A.C., and overseen and directed by K.G.L. All authors participated in the research and in the article preparation. All authors have read and agreed to the published version of the manuscript.
Funding: This research was supported by the United States Environmental Protection Agency (US EPA), Office of Research and Development’s (ORD) research programs: Sustainable and Healthy Communities (SHC 2.62.4).
Data availability statement: All data will be available at the NIH-PMC website.
Disclaimer
The U.S. Environmental Protection Agency (EPA) through its Office of Research and Development collaborated in the research described here. It has been subjected to the Agency’s peer review and has been approved as an EPA publication. Mention of trade names or commercial products does not constitute endorsement or recommendation by the EPA for use. The findings and the conclusions in this report are those of the authors and do not necessarily represent the views of the US EPA.
- Riggs MA, Rao CY, Brown CM, Van Sickle D, Cummings KJ, et al. Resident cleanup activities, characteristics of flood-damaged homes and airborne microbial concentrations in New Orleans, Louisiana, October 2005. Environ Res. 2008; 106: 401−409. PubMed: https://pubmed.ncbi.nlm.nih.gov/18199434/
- Hoppe KA, Metwali N, Perry SS, Hart T, Kostle PA, et al. Assessment of airborne exposures and health in flooded homes undergoing renovation. Indoor Air. 2012; 22: 446-456. PubMed: https://pubmed.ncbi.nlm.nih.gov/22519834/
- Quansah R, Jaakkola MS, Hugg TT, Heikkinen SA, Jaakkola JJ. Residential dampness and molds and the risk of developing asthma: a systematic review and meta-analysis. PloS One. 2012; e47526. PubMed: https://pubmed.ncbi.nlm.nih.gov/23144822/
- Major JL, Boese GW. Cross section of legislative approaches to reducing indoor dampness and mold. Public Health Manag Pract. 2017; 23: 388–395. PubMed: https://pubmed.ncbi.nlm.nih.gov/27977504/
- Shinohara N, Tokumura M, Hashimoto K, Asano K, Kawakami Y. et al. Fungal levels in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone after the Great East Japan Earthquake. J Air Waste Manag Assoc. 2017; 67: 1106-1114. PubMed: https://pubmed.ncbi.nlm.nih.gov/28541772/
- European Collaborative Action: Biological Particles in Indoor Environments. Report No. 12: EUR 14988 EN. 1993.
- Vesper S. Traditional mould analysis compared to a DNA-based method of mould analysis. Crit Rev Microbiol. 2011; 37: 15-24. PubMed: https://pubmed.ncbi.nlm.nih.gov/20874612/
- Haugland RA, Varma M, Wymer LJ, Vesper SJ. Quantitative PCR of Selected Aspergillus, Penicillium and Paecilomyces Species. Sys Appl Microbiol. 2004; 27: 198-210. PubMed: https://pubmed.ncbi.nlm.nih.gov/15046309/
- Vesper S, McKinstry C, Haugland R, Wymer L, Bradham K, Ashley P, et al. Development of an environmental relative moldiness index for US homes. J Occup Environ Med. 2007; 49: 829-833. PubMed: https://pubmed.ncbi.nlm.nih.gov/17693779/
- Vesper S, Wymer L. The relationship between Environmental Relative Moldiness Index values and asthma. Int J Hyg Environ Health. 2016; 219: 233-258.
- Cox J, Isiugo K, Ryan P, Grinshpun S, Yermakov M, et al. Effectiveness of a portable air cleaner in removing traffic-related aerosol particles. Indoor Air. 2018; 28: 818-827. PubMed: https://pubmed.ncbi.nlm.nih.gov/30133950/
- Vesper S, Prill R, Wymer L, Adkins L, Williams R, et al. Mold contamination in schools with either high or low prevalence of asthma. Ped Allergy Immun. 2015; 26: 49-53. PubMed: https://pubmed.ncbi.nlm.nih.gov/25511604/
- Solomon GM, Hjelmroos-Koski M, Rotkin-Ellman M, Hammond SK. Airborne mold and endotoxin concentrations in New Orleans, Louisiana, after flooding, October through November 2005. Environ Health Perspec. 2006; 114: 1381−1386. PubMed: https://pubmed.ncbi.nlm.nih.gov/16966092/
- Rao CY, Riggs MA, Chew GL, Muilenberg ML, Thorne PS, et al. Characterization of airborne molds, endotoxins, and glucans in homes in New Orleans after Hurricanes Katrina and Rita. Appl Environ Microbiol. 2007; 73: 1630−1634. PubMed: https://pubmed.ncbi.nlm.nih.gov/17209066/
- Schwab KJ, Gibson KE, Williams DL, Kulbicki KM, Lo CP, et al. Microbial and chemical assessment of regions within New Orleans, LA impacted by Hurricane Katrina. Environ Sci Technol. 2007; 41: 2401-246. PubMed: https://pubmed.ncbi.nlm.nih.gov/17438793/
- Alderman K, Turner LR, Tong S. Floods and human health: a systematic review. Environ Int. 2012; 47: 37-47. PubMed: https://pubmed.ncbi.nlm.nih.gov/22750033/
- Chew GL, Wilson J, Rabito FA, Grimsley F, Iqbal S, et al. Mold and endotoxin levels in the aftermath of Hurricane Katrina: a pilot project of homes in New Orleans undergoing renovation. Environ Health Perspect. 2006; 114: 1883−1589. PubMed: https://pubmed.ncbi.nlm.nih.gov/17185280/
- Curtis L, Ross M, Persky V, Scheff P, Wadden R, et al. Bioaerosol concentrations in the quad cities 1 year after the 1993 Mississippi River floods. Indoor Built Environ. 2000; 9: 35−43.
- Fabian MP, Miller SL, Reponen T, Hernandez MT. Ambient bioaerosol indices for indoor air quality assessments of flood reclamation. J Aerosol Sci. 2005; 36: 763−783.